Semiconducting coolers Pelte |
Humidity, % | |||||||||
Temperature Surrounding medium, °C |
30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 |
30 | 11 | 13 | 15 | 17 | 18 | 20 | 21 | 23 | 24 |
29 | 10 | 12 | 14 | 16 | 18 | 19 | 20 | 22 | 23 |
28 | 9 | 11 | 13 | 15 | 17 | 18 | 20 | 21 | 22 |
27 | 8 | 10 | 12 | 14 | 16 | 17 | 19 | 20 | 21 |
26 | 7 | 9 | 11 | 13 | 15 | 16 | 18 | 19 | 20 |
25 | 6 | 9 | 11 | 12 | 14 | 15 | 17 | 18 | 19 |
24 | 5 | 8 | 10 | 11 | 13 | 14 | 16 | 17 | 18 |
23 | 5 | 7 | 9 | 10 | 12 | 14 | 15 | 16 | 17 |
22 | 4 | 6 | 8 | 10 | 11 | 13 | 14 | 15 | 16 |
21 | 3 | 5 | 7 | 9 | 10 | 12 | 13 | 14 | 15 |
20 | 2 | 4 | 6 | 8 | 9 | 11 | 12 | 13 | 14 |
Except the specified features, it is necessary to consider and a number of the specific circumstances linked to usage of thermoelectric Пельтье units as a part of coolers, high-powered central processor units of powerful computers applied to cooling.
The architecture of modern processors and some system programs provide change energopotreblenija depending on loading of processors. It allows to optimise them energopotreblenie. By the way, it is provided also by standards energosberezhenija, the supported some functions which have been built in a firmware of modern computers. In usual conditions optimisation of operation of the processor and it energopotreblenija well affects as a thermal mode of the processor, and the common temperature balance. However it is necessary to mark, that modes with periodic change energopotreblenija can badly be combined with resources of cooling of the processors using Пельтье units. It is linked by that existing coolers Pelte, as a rule, are calculated for continuous operation. In this connection, the elementary coolers Pelte which is not possessing control devices, it is not recommended to use together with cooling programs, such as, for example, CpuIdle, and also with operating systems of Windows NT/2000 or Linux.
In case of processor transition in a mode reduced energopotreblenija and accordingly heat releases probably considerable lowering of temperature of tank and a processor chip. Subcooling of a kernel of the processor can call in some cases the time termination of its working capacity, and as the result, proof lag of the computer. It is necessary to remind, that according to the documentation of the corporation of Intel the minimum temperature at which correct operation of serial processors of Pentium II is guaranteed and Pentium III, usually makes +5 °C though as practice shows, they perfectly work and at lower temperatures.
Some problems can arise and as a result operations of some intrinsic functions, for example, what exercise administration of fans of coolers. In particular, control modes energopotrebleniem the processor in some computer systems provide change of speed of rotation of cooling fans through the built in hardware of the motherboard. In usual conditions it considerably improves a thermal mode of the processor of the computer. However in case of usage of the elementary coolers Pelte reduction of speed of rotation can already lead to deterioration of a thermal mode with fatal result for the processor owing to its overheat working Пельтье unit which except performance of functions of the thermal pump, is a powerful source of additional heat.
It is necessary to mark, that, as well as in case of central processor units of computers, coolers Pelte can be good alternative to traditional resources of cooling of the video chip sets used as a part of modern high-powered videoadapters. Operation of such video chip sets is accompanied by a considerable heat release and usually is not subject to an abrupt change of modes of their functioning.
To eliminate problems with modes changed energopotreblenija, calling condensation of a moisture from air and possible subcooling, and in some cases even an overheat of protected units, such as processors of computers, it is necessary to refuse usage of similar modes and of some intrinsic functions. However as alternative it is possible to use the systems of cooling providing intellectual controls by coolers Pelte. Such resources can inspect not only operation of fans, but also to change functional modes of the thermoelectric units used as a part of active coolers.
There were messages on experiments on embedding of miniature Пельтье units directly in chips of processors for cooling of their most critical structures. Such solution promotes the best cooling at the expense of lowering of a thermal resistance and allows to raise an operating frequency and productivity of processors considerably.
Operations in a direction of perfection of systems of support of optimal temperature modes of electronic units are carried on by many research laboratories. And the systems of cooling providing usage of thermoelectric Пельтье units, are considered extremely perspective.